How Do You Know When to Replace the Batteries on a Fisher Wallace Stimulator?

Bit Fisher

How-do-you-do. I'm Flake Fisher, president of Fisher Wallace Laboratories. Our portable medical device is chosen the Fisher Wallace stimulator and is cleared past the FDA for the treatment of depression, insomnia, anxiety, and pain. It's called a stimulator because it delivers a general electrical pulse that stimulates the brain to produce serotonin and other neuro-chemicals required for salubrious mood and sleep. Information technology'southward been proven in multiple published studies and is preferred by doctors at Harvard, NYU, Cornell, and other superlative institutions. In this video, I'll show you how to use the device to treat low, insomnia, and anxiety. You tin refer to the instruction manual included with every device regarding the handling of pain.

The device comes in five parts; the wires, the base unit, the sponge applicators, the headband, and the body band. First, place the base of operations unit in your mitt and open the battery compartment by pushing the locking slide downwards and lifting the back case off the unit. Following the diagram, place the 2 AA batteries in the compartment and reclose the instance.

Side by side, open up the caput set packet and connect the black and carmine wires to the two white caps. Insert the black wire into the hole with the black dot, and the red wire into the hole with the ruby dot. The two yellowish discs inside the caput set up caps are sponges that volition expand when wet. Take the sponge applicators and dip them thoroughly into a glass of cold h2o. Squeeze out the excess water and place them on the table. To use the device to care for depression, insomnia, and anxiety, take the head band and identify information technology above your ears with the front of the band resting just above your eyebrows.

The sponge applicators are then placed deeply under the head band, but above the side burns. If yous have long hair, make sure to place the applicators under the pilus, as close to the scalp as possible. There's a cycle on the right side of the device that should be turned clockwise to the off position. You'll hear a click when the device turns off.Fisher Wallace Device

To turn the device on, turn the wheel counter clockwise. You lot'll hear the click again and y'all'll meet the green calorie-free come on. If yous do not run into the green calorie-free come on, either the batteries are non installed properly, or the batteries have been depleted. One time the device is on, continue to turn the wheel until you encounter the showtime yellow calorie-free come on. This is yellowish light number one. The xanthous lights will only come up on if the device is successfully conducting. If yous accept also much pilus in the way or if the sponges are not wet plenty, the yellow lights will not come up on.

Yellow low-cal number 2 is the setting we recommend starting with to treat depression, insomnia, and anxiety. If you do not experience results at level two after two weeks, increase the setting to level three or four. If you utilize the device at level three or four, you lot may notice some flashing lights in your peripheral vision. This is a normal stimulation of the optic nerve and is perfectly safe. You tin can apply the device while you work, read, relax, or utilize the computer.

The device volition stay on for 20 minutes, after which y'all will hear an audible beep audio, turning the device off and catastrophe the session. The device should be used on a daily basis, ideally twice a day for at least 30 days before making a decision to keep information technology or return it for a refund. If the device completely relieves your symptoms, you lot may start using it on a maintenance basis, two or 3 times a calendar week.

Our device has been on the market place since 1991 and in that location is no evidence of negative effects from long term utilise. This is another advance of using our device in comparison to drug therapy. The device may also exist used on the body to treat chronic pain, including neuropathy, arthritis, back pain, and other forms of chronic and acute hurting.

To store the device, accept off the head ring and wrap the head ready around the base unit. When storing the device in its case, leave the sponges on the exterior of the handbag so they can dry out thoroughly.

The device may be used with or without medication and frequently starts to salve symptoms during the outset week of utilize. Some patients require 2 to four weeks to see results, so don't be discouraged if results take a bit longer to experience. If you have any questions, our highly trained customer service representatives are available to assist on a daily basis. Thanks for considering the Fisher Wallace stimulator. I truly hope it will assist you feel better.


Health Disclaimer. Copyright ©2013. Published with permission.

Related Products: See Fisher Wallace sponges and the Harmonizer.

scottstals1982.blogspot.com

Source: https://www.avivahealth.com/blogs/articles/fisher-wallace-instructions